madIR-D01 Sensor System

Microprocessor equipped NDIR Measuring cells
CO2 flow sensor using NDIR technology in ABS casing with optional display
IR sensors in one channel configuration. Available for many measuring ranges from 2000 ppm to 100 % for a variety of industrial applications.
Properties
  • Using microprocessor technology, all on one board
  • Fast reaction time (T90 < 45 seconds.)
  • Zeroing of the sensor: manually over zero button or externally over contacts
  • Automatic permanent check of sensors function. Necessity for calibration indicated by LED.
  • Automatic temperature compensation
Pictures
Product info
Brochure CO2 (54 kB))
Brochure CH4 (54 kB)
Control software (25 MB)
Working modes
  • "Smart Zero" - automatic correction of sensor zero using values from the previious 1 to 30 days
  • Continuous operation in 3 modes - zero, measure, standby
  • Continuous operation with timetable (24 hour cycle)
  • Continuous operation with permanent measurement (may be zeroed externally)
Standard configuration
  • ABS housing
  • Linear voltage output - active range (begin and end) may be user-configured within the nominal range 0....10 V.
  • Linear current output - active range (begin and end) may be user-configured within the nominal range 4....20 mA
  • Interface RS232C for changing the sensor settings and for data-logging
  • Digital output (0/5 V) – shows operating state of the sensor (0 V-measurement / 5 V-zeroing or standby)
  • Digital output (0/5 V) – shows the operating state of the pump ( 0V-off / 5 V-on)
  • Digital PWM output (0/5 V) - programmable output
  • Zeroing of sensor either manually using integrated button or externally over contacts
  • Power supply 13...30 VDC or 9...24 VAC, max 3 W
Optional equipment
  • Membrane pump test gas or zero gas
  • Display module
  • Data storage on 256 MB MMC
  • USB connection with madur adapter
Processing and display of measurement values
  • Measured gas concentration in [ppm] or [%] as:
    • Measured values in digital form over RS232
    • Measured value stored in digital form on internal memory card (option)
    • Measured value over analogue outputs 0/4 - 20 mA and 0 - 5/10 V
    • Measured values on internal display (option)
  • PC programme for changing the sensor settings and for data-logging
Operating data

Parameter

madIR-D01
Measured gases
CO, CO2, CH4
Measuring method infra-red absorption, 1 channel with light modulation
Housing ABS
Sampling Diffusion or flow
Operating temperature 0 ÷ +50°C
Storage temperature -20 ÷ +70°C
Humidity 5 ÷ 90 %, non-condensing
Voltage supply 13...30 VDC or 9...24 VAC
Power max. 3 W
Analogue outputs

Begin and end can be user-configured within the range
Current: 4 - 20 mA, linear
Voltage: 0 - 10 V, linear

Interface RS 232C
Averaging time 2 ÷ 60 s user-configured
Calibration 10 point calibration stored in EEPROM
Recalibration not necessary. Falls erwünscht 2-Punkte Kalibrierung möglich
Size of Printplatte

105 x 40 x 30 mm

Size of shot ABS housing 120 x 80 x 55 mm
Size of long ABS housing

240 x 80 x 55 mm

Weight (short / long housing) 220 g/330 g

Measurement Channel Technical Data
Gas Range Resolution Detection limit Accuracy Resp. time (t90)
CO - carbon monoxide-volumetric concentration

CO2 - carbon dioxide-volumetric concentration

CH4 - methane-volumetric concentration
0...100 % 0.10 % 0.10 % ± 0.5 % abs., or 3 % rel. 45 s
0....50 % 0.10 % 0.10 % ± 0.3 % abs., or 3 % rel.
0...25 % 0.01 % (100 ppm) 0.01 % (100 ppm) ± 0.15 % abs., or 3 % rel.
0...10 % 0.01 % (100 ppm) 0.01 % (100 ppm) ± 0.05 % abs., or 3 % rel.
0...5% 0.01 % (100ppm) 0.01 % (100ppm) ± 0.03 % abs., or 3 % rel.
0...2,5% 0.001 % (10 ppm) 0.001 % (10 ppm) ± 0.015 % abs., or 3 % rel.
a

Copyright © 2008  madur. All rights reserved.