GA-21Bio plus
Portable landfill analyser using electrochemical and IR gas sensors. |
|
|
The gas analyser GA-21Bio plus is designed for use in waste plants where it is necessary to measure the gases produced and the emissions from a connected power or heat generation station. This is now possible with a single instrument thanks to the use of the most modern technology. Like all our instruments, the GA-21Bio plus is manufactured to give a long working life. Using the optional dryer it is possible to carry out longer term measurements. Three extra analogue inputs allow the simultaneous measurement of a voltage or current signal and a temperature. This makes it ideally suited for measurements on district heating plants. Manufactured with EN50379 in mind.
|
|
|
|
|
|
|
|
|
|
|
|
|
- Measurement of gas concentrations
- Gas concentrations measured with NDIR sensors: CO2, CH4
- Gas concentrations measured with electrochemical sensors: O2, CO
- Toxic gas concentrations measured with electrochemical sensors: CO, NO, NO2, SO2, H2S. Please ask for quote for other gases.
- Measurement of other parameters
- Measurement of gas and ambient temperatures
- Pressure, draft and differential pressure measurements with 1 Pa resolution
- Soot test according to Bacharach with a pump flow of 1.62 l/min
- Three analogue inputs (1 current/voltage, 1 thermocouple, 1 thermistor)
- Calculation
- Calculation of absolute and relative mass concentrations & relative emissions
- Calculation of all relevant combustion parameters
- Processing and presentation of measured data
- All results shown on display
- Averaging of all measured values. Averaging time: 10 sec - 60min
- Graphical presentation of all measured values as diagram (option)
- Memory capacity for 1024 sets of data, organised into 10 data banks
- Up to 9 separate items in a data set
- User definition of the 9 items
- Memory capacity for 30 reports
- Data logger function for the analogue inputs
- All measured values, stored values or displays can be printed on the internal printer.
- Powerful PC program for analyser settings and data communication
- Software-Eigenschaften
- International compatibility (language, date format etc.)
- Password protection for settings
- Automatic zeroing when the analyser is switched on
- Calibration of O2/CO2 during use
- All parameters programmable
- List of 22 common fuels
- 10 further freely programmable fuels
- Permanent automatic check of the instrument with acoustic warning and full information in the "control list"
- Compensation of cross sensitivity and temperature drift of gas sensors
- Hardware capabilities
- Electronic regulation of the pump flow rate
- Integrated clock/calendar
- Internal 57 mm dot-matrix printer
- Power from rechargeable battery or mains
- Big (70 x 60 mm) LCD display with backlighting (Graphics or 11 x 21 characters)
- Gas probe with thermocouple and condensate trap
- Power for heated probe holder during mains operation
- RS-232C interface and multifunctional PC program
|
|
|
|
|
|
|
|
|
|
|
|
- Size of case W x H x D: 460 x 160 x 170 mm
- Weight w/o probe: 6.2 kg
- Display size: Graphical - LCD, with backlighting and variable contrast, 128 x 112 pixels, 75 x 64 mm
- Printer: high-speed dot matrix printer with graphics capability for 57 mm normal paper
- Data memory: Memory for 30 reports and 10 banks containg a total of 1024 sets of data
- CO - measurement channel: Separate from the other gas channels. If the freely programmable maximum is exceeded then the sensor is purged with air, without interrupting the other measurements
- Interface: RS232C
- Power supply: 110 or 230 VAC 50 ÷ 60 Hz
- Charging time: Lead-acid battery 12 V/2.2 Ah, charging time 10 h, working time from battery approx. 6 h (w/o dryer))
- Gas pump: Membrane pump, electronically regulated at 90l/h
- Probe: Heated for soot test
- Probe length: 300 mm (other options available)
- Length of gas line: 3 m
- Gas filter: In line filter 20 µm
- Operating temperature: 10 °C ÷ 50°C
- Storage temperature: -20 °C ÷ +55 °C
|
|
|
|
|
|
|
|
|
| Parameter |
Method
|
Indication range
|
Display resolution
|
Accuracy
|
Detection limit
|
Resp. time (t90)
|
| Gases measured in standard configuration |
| O2 - oxygen, volumetric concentration |
electrochemical gas sensor |
0..25 %
|
0.01 %
|
0.2 %
|
0.2 %
|
45 s
|
|
| CO - carbon monoxide, volumetric concentration |
electrochemical gas sensor |
0..20000 ppm
|
1 ppm
|
±5 ppm or
5 % rel.
|
5 ppm
|
45 s
|
| COmg - carbon monoxide, mass concentration |
calculated from volumetric concentration of CO |
0...
|
1 mg/Nm3
|
± 10 mg/Nm3 or 5 % rel.
|
10 mg/Nm3
|
45 s
|
| COrel - carbon monoxide, mass concentration relative to O2 |
calculated from volumetric concentration of CO and O2 |
0...
|
1 mg/Nm3
|
± 10 mg/Nm3 or 5 % rel.
|
10 mg/Nm3
|
45 s
|
|
| CO2 - carbon dioxide volumetric concentration |
IR sensor |
0...100 %
|
0.1 %
|
+/- 3 % rel., or 0.5 % abs. |
0.2 %
|
45 s
|
| CH4 - Methane, volumetric concentration |
IR sensor |
0...100 %
|
0.1 %
|
+/- 3 % rel., or 0.5 % abs. |
0.2 %
|
45 s
|
|
| Gases measured with optional electrochemical sensors |
| H2S - volumetric concentration of hydrogen sulphide |
electrochemical gas sensor |
0..1000 ppm
|
1 ppm
|
±5 ppm or 5 % rel.
|
5 ppm
|
45 s
|
| H2Smg - mass concentration of hydrogen sulphide |
calculated from volumetric concentration of H2S |
0...
|
1 mg/Nm3
|
±10 mg/Nm3 or 5 % rel.
|
10 mg/Nm3
|
45 s
|
| H2Srel - mass concentration of hydrogen sulphide relative to O2 |
calculated from volumetric concentration of H2S and O2 |
0...
|
1 mg/Nm3
|
±10 mg/Nm3 or 5 % rel.
|
10 mg/Nm3
|
45 s
|
|
| NO / NOx - volumetric concentration of nitrogen oxides. |
electrochemical gas sensor |
0..5000 ppm
|
1 ppm
|
±5 ppm or 5 % rel.
|
5 ppm
|
45 s
|
| NOmg/NOxmg - mass concentration of nitrogen oxides |
calculated from volumetric concentration of NO |
0...
|
1 mg/Nm3
|
±15 mg/Nm3 or 5 % rel.
|
15 mg/Nm3
|
45 s
|
| NOrel / NOxrel - mass concentration of nitrogen oxides relative to O2 |
calculated from volumetric concentration of NO and O2 |
0...
|
1 mg/Nm3
|
±15 mg/Nm3 or 5 % rel.
|
15 mg/Nm3
|
45 s
|
|
| NO2 - volumetric concentration of nitrogen dioxide |
electrochemical gas sensor |
0..1000 ppm
|
1 ppm
|
±5 ppm or 5 % rel.
|
5 ppm
|
45 s
|
| NO2mg - mass concentration of nitrogen dioxide |
calculated from volumetric concentration of NO2 |
0...
|
1 mg/Nm3
|
±15 mg/Nm3 or 5 % rel.
|
15 mg/Nm3
|
45 s
|
| NO2rel - mass concentration of nitrogen dioxide relative to O2 |
calculated from volumetric concentration of NO2 and O2 |
0...
|
1 mg/Nm3
|
±15 mg/Nm3 or 5 % rel.
|
15 mg/Nm3
|
45 s
|
|
| SO2 - volumetric concentration of sulphur dioxide. |
electrochemical gas sensor |
0..5000 ppm
|
1 ppm
|
±5 ppm or 5 % rel.
|
5 ppm
|
45 s
|
| SO2mg - mass concentration of sulphur dioxide. |
calculated from volumetric concentration of SO2 |
0...
|
1 mg/Nm3
|
±15 mg/Nm3 or 5 % rel.
|
15 mg/Nm3
|
45 s
|
| SO2rel - mass concentration of sulphur dioxide relative to O2 |
calculated from volumetric concentration of SO2 and O2 |
0...
|
1 mg/Nm3
|
±15 mg/Nm3 or 5 % rel.
|
15 mg/Nm3
|
45 s
|
|
| Other measured values |
| Tgas - flue gas temperature |
Thermocouple |
-10..1000°C
|
1°C
|
± 2 °C or
1.5 % rel.
|
1 °C
|
30 s
|
| Tamb - ambient temperature |
Thermistor |
-10..100°C
|
1°C
|
± 1 °C
|
1 °C
|
30 s
|
|
| U/I - external input |
ADC |
-20...+20 V -20...+20 mA
|
0.01 V 0.01 mA
|
±0.02 V ±0.02 mA
|
0.01 V 0.01 mA
|
10 s
|
| T1 - external input |
Thermocouple |
0...1600°C
|
1°C
|
± 2 °C or 1.5 % rel.
|
1 °C
|
10 s
|
| T2 - external input |
Thermistor |
-20...1000°C
|
1°C
|
± 2 °C or 1.5 % rel.
|
1 °C
|
10 s
|
| Pressure |
DMS bridge |
-25 hPa ...
+25 hPa
|
0.1 Pa
|
± 2 Pa or
5 % rel.
|
1 Pa
|
10 s
|
|
| TI (CO/CO2-Toxic Index) |
calculated |
0...0.01
|
0.0001
|
5 % rel.
|
0
|
10 s
|
| Lambda - excess air number |
calculated |
1..10
|
0.01
|
2 % rel.
|
0
|
10 s
|
| qA - combustion losses |
calculated |
0..100 %
|
0.1%
|
2 % rel.
|
0 %
|
10 s
|
| Eta - efficiency |
calculated |
0..120 %
|
0.1%
|
2 % rel.
|
0 %
|
10 s
|