Stationary Gas Monitor
Stationary gas monitor mamos-300 with integrated peltier gas dryer

The maMoS-300/400 is a high quality stationary monitor for continuous measurement of three or four gas components. It is produced using all the newest technological developments. The monitor comes complete with filter, Peltier dryer and condensate pump.
It can be fitted with either infrared or electrochemical sensors or both. The possible sensors are: (electrochemical) O2, CO, NO, NO2, SO2, H2S or: (IR) CO2, N2O, CH
4.
The gas monitor is fitted with analogue outputs for current and voltage to allow control functions as well as measurement. There is also a digital data output if needed.

The instrument operates fully automatically in one of two possible cycle forms:

  • continuous
  • Measurement on timetable

Both of these cycle types is freely programmable. Details

Pictures
Product info
Folder maMoS-300 (75 kB)
Folder maMoS-400 (75 kB)
Manual (6 MB)
Control software (15 MB)
Application possibilities
  • Biogas plants
  • Landfills
  • Greenhouses
  • Stationary control of combustion systems
  • Incinerators
  • Safety such as CO2 (0...2000 ppm) or CH4 (0...5 %)
Properties

Measurement of gas concentrations

  • Gas concentrations measured with NDIR sensors: CO, CO2, CH4, N2O
  • Gas concentrations measured with electrochemical sensors: CO, NO, NO2, SO2, H2S. Please ask for quote for other gases
  • O2 using partial pressure sensor

Other measurements

  • Atmospheric pressure
  • Differential pressure
  • Temperature using thermocouples
  • Temperature using thermistors Pt-500

Processing and presentation of measured data

  • Gas concentrations shown as ppm or mg/m3
  • All results shown as instantaneous values on display
  • Powerful PC program for analyser settings and data communication
  • Optional: Datalogger with 256MB MMC (Memory card)
  • Optional calculation of combustion parameters: Lambda, qA, Eta
  • Optional calculation of NOx from NO or NO and NO2

Software capabilities

  • Stationary operation: Zeroing and measurement times user programmable
  • Permanent automatic check of the instruemnt
  • Compensation of cross sensitivity and temperature drift of gas sensors

Hardware capabilities

  • ABS housing for wall-mounting with internal ventilation
  • Microprocessor controlled
  • IR sensors (CO, CO2, CH4, N2O) with short reaction time (T90 < 15 seconds)
  • Integrated Peltier sample conditioner with condensate pump and filter
  • Solenoid valve for automatic ventilation during zeroing
  • Membrane pump for sample extraction
  • 4 current (0/4 - 20 mA) and 4 voltage (0 - 10 V). Freely allocated to the measurment channels
  • Up to 3 LCD displays. Freely allocated to the measurement channels
  • RS232C or RS485 connection for data transfer
  • PC programme for quick and simple configuration of the instrument and data transfer
  • Optional integrated clock/calendar
  • Optional: Converter for connection to USB or Ethernet
Operating data
Parameter Description
Size W x L x H: 420 x 360 x 140 mm
Weight without power supply ca. 5 kg
Supply 24 VAC / 120 W
Gas pump Membrane pump 1.5 l/min
Display LCD, for up to 4 components
Data logger MMC Card 256 MB
Analoge Ausgänge Current 0/4 - 20 mA, Voltage 0 - 10 V, linear for each channel
Interface RS 232C
Operating temperature 0°C ÷ 50°C
Storage temperature -20 ÷ +55°C
Humidity 5 ÷ 90 %, non-condensing

Only NDIR sensors
Parameter Description
Measuring method
NDIR light absorption, 1 channel with light modulation
Averaging time
2 ÷ 60 s freely programmable
Calibration
10 point calibration, stored in EEPROM. Correction of the calibration curve possible with zeroing and one calibration gas.
Recalibration
not usually necesary. If desired, a 2 point calibration can be carried out by the user.

Only electrochemical sensors
Parameter Description only for electrochemical sensors
Measuring method
electrochemical
Averaging time
2÷30 s freely programmable
Calibration
2 point calibration, variable
Recalibration
At least every 12 months

Technical data
Component Method Range Resolution Detection Level Accuracy Time (T90)
NDIR sensors
CO - Carbon monoxide-Volume concentration

CO2 - Carbon dioxide-Volume concentration

CH4 - Methane-Volume concentration
IR Sensor 0...100 % 0.10 % 0.10 % +/- 3 % rel.,
or 0.5 % abs.
45 s.
0....50 % 0.10 % 0.10 % +/- 3 % rel.,
or 0.3 % abs.
0...25 % 0.01 % (100 ppm) 0.01 % (100 ppm) +/- 3 % rel.,
or 0.15 % abs.
0...10 % 0.01 % (100 ppm) 0.01 % (100 ppm) +/- 3 % rel.,
or 0.05 % abs.
0...5 % 0.01 % (100 ppm) 0.01 % (100 ppm) +/- 3 % rel.,
or 0.03 % abs.
0...2.5 % 0.001 % (10 ppm) 0.001 % (10 ppm) +/- 3 % rel.,
or 0.015 % abs.
N2O - Nitrous oxide -Volume concentration 0...500 ppm 1 ppm 1 ppm +/- 3 % rel.,
or 5 ppm abs.
Electrochemical sensors
CO - Carbon monoxide, Volume concentration Electrochemical
sensors
0...20000 ppm 1 ppm 1 ppm +/- 5 % rel.,
or 5 ppm abs.
45 s.
NO / NOx - Nitric oxide, Volume concentration 0...5000 ppm 1 ppm 1 ppm
NO2 - Nitrogen dioxide, Volume concentration 0...1000 ppm 1 ppm 1 ppm
SO2 - Sulphur dioxide, Volume concentration 0...5000 ppm 1 ppm 1 ppm
H2S - Hydrogen sulphide, Volume concentration 0...1000 ppm 1 ppm 1 ppm
H2 - Hydrogen, Volume concentration 0...2000 ppm 1 ppm 1 ppm
Partial pressure sensor
O2 - Oxygen, Volume concentration partial pressure sensor 0...25 % 0.01 % 0.01 % +/- 5 % rel.,
or 0.2 % abs.
45 s.
a